model no. description range frequency
response
(-3dB)
independent
linearity
sealing
Hydraulic and pneumatic cylinder position feedback
FDP100 Cylinder Linear Position Sensor FDP100 Cylinder Linear Position Sensor 20...600 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
Position feedback for industrial and scientific applications
FDP101 Stand Alone Linear Position Sensor FDP101 Stand Alone Linear Position Sensor 50...600 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
FDP103 Short Stroke Linear Position Sensor FDP103 Short Stroke Linear Position Sensor 10...50 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% IP65 (connector)
IP67 (cable output)
FDP106 Internally Mounted Cylinder Sensor With External Electronics FDP106 Internally Mounted Cylinder Sensor With External Electronics 20...600 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
FDP111 Rugged Stand Alone Linear Position Sensor FDP111 Rugged Stand Alone Linear Position Sensor 50...600 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
FDP112 Gauge Head Position Sensor FDP112 Gauge Head Position Sensor 10...50 mm > 10 kHz < ± 0,25% IP67
FDP114 Submersible Stand Alone Linear Position Sensor FDP114 Submersible Stand Alone Linear Position Sensor 50...600 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP68 10 bar
FDP115 Rugged Submersible Stand Alone Linear Position Sensor FDP115 Rugged Submersible Stand Alone Linear Position Sensor 50...600 mm > 10 kHz
> 300 Hz (4-20 mA)
< ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP68 10 bar
FDP117 Slim-line Linear Position Sensor FDP117 Slim-line Linear Position Sensor 10...300 mm > 10 kHz < ± 0,25% IP67

 

(Intrinsically safe) Position Sensors for Hazardous Environments, such as:

1. Sensors for Gas/Vapour environments (see below table)
2. Sensors for Dust environments (Consult ALTHERIS)
3. Sensors for Mining environments (Consult ALTHERIS)

Intrinsically Safe Sensors for Gas/Vapour Atmospheres

  model no. description range frequency
response
(-3dB)
independent
linearity
sealing
Ex logoThe following sensors are ATEX approved to: Ex II 1G, EEx ia IIC T4 (Ta = -40°C to +80°C)
FDX100 Cylinder Linear Position Sensor FDX100 Cylinder Linear Position Sensor 20...600 mm > 10 kHz < ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
FDX101 Stand Alone Linear Position Sensor FDX101 Stand Alone Linear Position Sensor 50...600 mm > 10 kHz < ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
FDX103 Short Stroke Linear Position Sensor FDX103 Short Stroke Linear Position Sensor 10...50 mm > 10 kHz < ± 0,25% IP65 (connector)
IP67 (cable output)
FDX106 Internally Mounted Cylinder Sensor With External Electronics FDX106 Internally Mounted Cylinder Sensor With External Electronics 20...600 mm > 10 kHz < ± 0,25% up to 450 mm
< ±
IP65 (connector)
IP67 (cable output)
FDX111 Rugged Stand Alone Linear Position Sensor FDX111 Rugged Stand Alone Linear Position Sensor 50...600 mm > 10 kHz < ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP65 (connector)
IP67 (cable output)
FDX112 Gauge Head Position Sensor FDX112 Gauge Head Position Sensor 10...50 mm > 10 kHz < ± 0,25% IP67
FDX114 Submersible Stand Alone Linear Position Sensor FDX114 Submersible Stand Alone Linear Position Sensor 50...600 mm > 10 kHz < ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP68 10 bar
FDX115 Rugged Submersible Stand Alone Linear Position Sensor FDX115 Submersible Rugged Stand Alone Linear Position Sensor 50...600 mm > 10 kHz < ± 0,25% up to 450 mm
< ± 0,5% over 450 mm
IP68 10 bar
FDX117 Slim-line Linear Position Sensor FDX117 Slim-line Linear Position Sensor 10...300 mm > 10 kHz < ± 0,25% IP67

 

Ex logo The intrinsically safe sensors are available in the EX02 versions which are ATEX Qualified to Intrinsic Safety Specification:

The sensors are certified for use with a galvanically isolated three port barrier designed to supply the sensor with a nominal 5V and to transmit the buffered output to a safe area.

Intrinsically safe sensors are supplied with Pepperl + Fuchs Barriers with the following output options: