One of three wires of this strain gauge is made of copper-nickel alloy, while other two wires are made of ordinary copper. A T-type thermocouple is composed by a copper-nickel wire and a copper wire. Strain measurement by quarter bridge 3-wire method and temperature measurement by thermocouple are possible with one strain gauge. This gauge must be measured by TML data loggers.
Datasheet: FLA-T series straingauges temperature integrated
| Main Test Materials | Metal | Materials Backing | Epoxy |
|---|---|---|---|
| Operating Temperature | -20 to +80°C | Materials Element | Cu-Ni alloy foil T-thermocouple |
| Compensation range | +10 to +80°C | Strain limit | 3% (30000×10-6) |
| Bonding adhesive | CN,P-2 | Fatigue life at room temp. | 1×106 (±1500×10-6) |
Single element(G.F. 2.1 approx.)
0.08mm2 PVC lead wire pre-attached
Total resistance of lead wire per meter:0.44(Ω) (as for copper wire)
![]()

| type | gauge length (mm) |
gauge width (mm) |
Backing length (mm) |
Backing width (mm) |
resistance (Ω) |
Lead wires length |
|---|---|---|---|---|---|---|
| FLA-1T-11-3LT FLA-1T-17-3LT FLA-1T-23-3LT |
1 | 1.3 | 5 | 2.5 | 120 | 3-wire 3m |
| FLA-2T-11-3LT FLA-2T-17-3LT FLA-2T-23-3LT |
2 | 1.5 | 6.5 | 3 | 120 | 3-wire 3m |
| FLA-5T-11-3LT FLA-5T-17-3LT FLA-5T-23-3LT |
5 | 1.5 | 10 | 3 | 120 | 3-wire 3m |
Temperature integrated gauges are available for other series of strain gauges. Please contact ALTHERIS for details.