This gauge is designed for successful strain measurement on the concrete surface. It has a thin stainless-steel backing which prevents the penetration of moisture from the reverse side. It provides good electrical insulation to the concrete surface. The WFLM gauge has a moistureproof overcoating and integral lead in addition to stainless-steel backing. Stable measurement can be achieved by bonding the gauge with PS adhesive.

Datasheet: FLM-WFLM series Metal backing strain gauge

Main Test Materials Concrete, mortar Materials Backing Stainless steel
Operating Temperature -20 to +80°C Materials Element Ni-Cr alloy foil
Compensation range +10 to +80°C Strain limit 0.5%
(5000×10-6)
Bonding adhesive PS Fatigue life at room temp. 1×105
(±1000×10-6)

 

Single element(G.F. 2.0 approx.)

FLM straingauge schematic

type gauge
length
(mm)
gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Backing
thickness
(mm)
resistance
(Ω)
FLM-30-11 30 0.5 60 18 0.12 120
FLM-60-11 60 0.7 90 18 0.12 120

 

Single element(G.F. 2.0 approx.) [waterproof type]

0.09mm2 3-wire paralleled Polythylene leadwire pre-attached
Total resistance per meter : 0.4 (Ω)
Lead wire length : 3-wire paralleled Polyethylene lead wire of 2m long

WFLM straingauge schematic

type gauge
length
(mm)
gauge
width
(mm)
Backing
length
(mm)
Backing
width
(mm)
Backing
thickness
(mm)
resistance
(Ω)
WFLM-30-11-2LT 30 0.5 60 18 4 120
WFLM-60-11-2LT 60 0.7 90 18 4 120